EN 60068-2-75 Dimensions table of impact elements
IK code | IK00 | IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 | IK11 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Impact energy (Joule) | * | 0.14 | 0.20 | 0.35 | 0.50 | 0.70 | 1.00 | 2.00 | 5.00 | 10.00 | 20.00 | 50.00 |
Drop Heigth (mm) | * | 56 | 80 | 140 | 200 | 280 | 400 | 400 | 300 | 200 | 400 | 500 |
Mass (kg) | * | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.50 | 1.70 | 5.00 | 5.00 | 10.00 |
Material | * | P1 | P1 | P1 | P1 | P1 | P1 | S2 | S2 | S2 | S2 | S2 |
R (mm) | * | 10 | 10 | 10 | 10 | 10 | 10 | 25 | 25 | 50 | 50 | 50 |
D (mm) | * | 18.5 | 18.5 | 18.5 | 18.5 | 18.5 | 18.5 | 35 | 60 | 80 | 100 | 125 |
f (mm) | * | 6.2 | 6.2 | 6.2 | 6.2 | 6.2 | 6.2 | 7 | 10 | 20 | 20 | 25 |
r (mm) | * | – | – | – | – | – | – | – | 6 | – | 10 | 17 |
l (mm) | * | Must be adapted to the appropriate mass | ||||||||||
Swing hammer | * | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Spring hammer | * | Yes | Yes | Yes | Yes | Yes | Yes | No | No | No | No | No |
Free fall hammer | * | No | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
What types of impact elements are there?
There are 3 types of impact elements:
- Spring hammer
- Pendulum hammer
- Vertical hammer
It is not stipulated which impact element used. The spring hammer is due to its compact design and the relatively low mass only able to test IK01 to IK06. The pendulum hammer and the vertical hammer are only used between IK07 and IK11 due to their high weight.
IMPORTANT
Bullets that only correspond to the correct mass are not standard-compliant impact elements and therefore not permitted for tests according to EN 60068-2-75. There are standards in which steel bullets are specified (e.g. EN60601) but this is explicitly not the case with EN 60068-2-75. The bullet has a different mass diameter ratio as well as a different speed on impact. It cannot be assumed that the same joule number achieves the standard-compliant result if the impact element deviates from the specifications. Especially with bullet diameters that are too small, the impact load is much higher than with correct diameters.
EN 60068-2-75 Impact components
IK code | Top | Download |
---|---|---|
IK01 - IK06 | ||
IK01 - IK06 | Striking Element IK01-IK06.pdf | |
IK07 | Striking Element IK07.pdf | |
IK08 | Striking Element IK08.pdf | |
IK09 | Striking Element IK09.pdf | |
IK10 | Striking Element IK10.pdf | |
IK11 | Striking Element IK11.pdf |
Impactinator® IK10 touchscreens are designed to meet impact resistance with severity level IK10 according to standard EN/IEC 62262. The touchscreen resists 20 joules of impact energy on the IK10 test.
The impact-resistance of our rugged monitors reliably complies with the IEC 60068-2-75 and IEC 62262 standards with IK10 glass or 20 Joule bullet impact. We offer proven standard solutions as well as special extremely impact-resistant and robust monitors tailored to your application.
We achieve the reliable IK10 requirement impact resistance with our Impactinator® glass even without a laminated glass construction. For the bullet impact test according to EN/IEC 62262, we achieve values of more than 40 joules for the central impact on 2.8 mm thin glass and exceed the requirements of the EN 60068-2-75 standard by more than 100%.